/communities/CC_Knowledge
IC200CPU001 - VersaMax CPU Module (GFK-1536)
- Id:
- 000036816
- Legacy Id:
- DO517
-
Average User Rating:
-
Your Rating:
-
Last Updated:
Wed Apr 13 15:44:57 GMT 2022
-
Date Created:
Mon Oct 11 15:46:00 GMT 2004
- Products:
VersaMax
-
Categories:
Data Sheets/IPIs
Note: CPU001-AA, BA, BB, BC, or BD are not upgradeable!
Rel. | Ver. | Date | IPI | Upgrade Kit | New Features | Problems Resolved |
QM | 2.36 | Mar-2022 | GFK-1536Y | N/A | N/A | Minor changes were implemented to the boot firmware to accommodate the new flash chip introduced during flash obsolesces activity. For this release, only the factory firmware kit will be updated. There is no change to the Web upgrade kit compared to the previous release. |
PL | 2.36 | Nov-2019 | GFK-1536X | N/A | N/A | Following Emerson’s acquisition of this product, changes have been made to apply appropriate branding and registration of the product with required certification agencies. No changes to material, process, form, fit or functionality. Firmware Revision 2.36 Upgrade Kit: 44A747796-G11 |
NL | 2.36 | Dec 2016 | GFK-1536W | N/A | N/A | EU RoHS compliant module per directive2011/65/EU dated 8-June-2011. No changes to features, performance or compatibility. FW changes to support the configurable memory of 42KB. |
LK | 2.35 |
Feb. 2012
| GFK-1536V | N/A | N/A |
Label change. No change to , features performance or compatibility
|
KK | 2.35 | Mar-10 | GFK-1536T | N/A | N/A | Changed manufacturing location. No change to compatibility, functionality or performance |
JK | 2.35 | Oct-08 | GFK-1536S | N/A | Updated PSOK signal circuit | |
HK | 2.35 | Sept-06 | GFK-1536P | N/A | Hardware part change. | |
GK | 2.35 | Oct-05 | GFK-1536p | 44A747796-G09 | |
1. Setting ERROR_TERM_SELECT and DERIVATIVE_ACTION in the Config Word no longer reverses sign of the PID derivative term.
2. Changing the Integral Rate parameter value of a PID function block from 2 to 1 does not cause a step change to the Integral Term and the Control Variable.
3. When Serial I/O and Hardware Flow Control are specified for Port 2 in the hardware configuration, transmissions from port 2 complete properly.
4. Using a Serial Port Setup COMMREQ to switch from one serial communications protocol to another will not cause a Corrupted User Memory Fault
|
FJ | 2.34 | Jun-04 | GFK-1536n | 44A747796-G08 |
- Filter for PID Derivative Term
- Higher Serial Comm Throughput
- Support for 32-bit register data using RTU Master Serial Protocol
|
- Protocol Change on Serial Port will not cause HMI disconnect
- Repeated Port Setup COMMREQs will not cause CPU SW Fault
- Changing Intregral Rate from 2-1 or 1-2 does not cause step change to Intregral Term or Control Variable
- Serial I/O Flow Control for Port 2 fix
|
EH | 2.31 | Jan-04 | GFK-1536m | |
| |
DH | 2.31 | Dec-02 | GFK-1536m | |
- Added Modbus RTU Master Communications Protocol
| |
DF | 2.20 | Apr-02 | GFK-1536k | |
- New baud rates for Serial I/O protocol: 1200 and 2400 (requires VersaPro software version 2.03 or later, or Cimplicity Machine Edition Logic Developer version 3.0 or later).
|
- Table values no longer cleared if configured for other than default
- Table search instruction max value index fix
- CPU kept serial line in transmit mode based on scan time
- Master Hardware Checksum Not Equal error if configurable memory size was changed
|
CE | 2.10 | Apr-01 | GFK-1536j | |
- Configurable user memory
- EZ Program Store Device
- High-density Analog I/O
- RTS (and turnaround) delay functionality for RTU and Serial IO
|
- Positive transition coil not set correctly
- Validation of status word for commreqs
- BIT_SEQ with length of one
- Clearing faults on MDL730 modules
- Programmer Attach feature when RTU protocol configured using a COMREQ
- Folder corruption occurs when loading 50 subroutines
|
BD | 1.50 | Dec-99 | GFK-1536g | |
- Support for Expansion I/O
|
- Trig Functions output results
- Overflow and Underflow conditions with Real Exponents
- Simultaneous load and store of subroutines
- End Function may be used within subblock
- Run/Stop keyswitch enable/disable
- Radian to Degree Function no longer returns +/- infinity
- Retentive negative transition coils are not set in first sweep
- Storing hardware configuration with passwords disabled
|
BC | 1.20 | Aug-99 | GFK-1536d | |
- Support for modules ALG240, ALG331, ALG620, ALG630
|
- Watchdog timer expires with booster power supply
- Faulted module present during autoconfiguration
- Intelligent module lost
- Hot-insertion of intelligent module can cause a fatal fault
- Word for word change can cause indeterminate CPU operation
|
BB | 1.10 | Mar-99 | GFK-1536c | |
- Support for intelligent I/O modules
- Scaling function blocks
- Drum Sequencer function block
|
- State of Force LED
- Hold Last State
- Fault Status bits %SC009-13
|
-
Attached Files
-
Posted: 4/13/2022
GFK-1536Y - Minor changes implemented to the boot firmware to accommodate the new flash chip introduced during flash obsolesces activity. For this release, only the factory firmware kit will be updated. There is no change to the Web upgrade kit compared to the previous release.
-
Posted: 3/3/2020
GFK-1536X, Following Emerson’s acquisition of this product, changes have been made to apply appropriate branding and registration of the product with required certification agencies. No changes to material, process, form, fit or functionality.
-
Posted: 7/12/2018
CPU001-NL: EU RoHS compliant module per directive2011/65/EU dated 8-June-2011. No changes to features,performance or compatibility. Firmware updated to version 2.36 to support the configurable
memory of 42KB.